Question 1

A deployment engineer is installing a PowerEdge XE8640 server in a rack with round holes. They cannot get the outer rail portion to fit flush with the rack frame.

What is the reason the outer rail is not flush with the frame?



Answer : C

Understanding Rail Types and Compatibility:

Dell PowerEdge servers, including the XE8640, come with rail kits designed for specific types of racks. The rail kits are tailored to fit racks with square holes or threaded holes, depending on the model and configuration.

Compatibility with Round-Hole Racks:

The PowerEdge XE8640 does not support installation in round-hole racks. The rail kits provided with the XE8640 are designed for 4-post racks with square holes or 4-post threaded racks. Attempting to install these rails in a round-hole rack will result in improper fitment and stability issues.

Common Installation Issues:

If the outer rail portion does not fit flush with the rack frame, it is often due to a compatibility issue with the rack type. Round-hole racks require specific rail kits that are different from those used for square or threaded hole racks.

Verifying Rack Type:

Before installation, verify the type of rack being used. Ensure that it matches the specifications outlined in the server's installation guide. Using the correct rack type ensures proper fitment and structural integrity.

Alternative Solutions:

If the current rack is a round-hole type, consider using a compatible rack with square or threaded holes for the XE8640. Alternatively, there might be adapters or conversion kits available that allow the use of standard rails in round-hole racks, although these are not typically recommended due to potential stability issues.

Reference and Documentation:

Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for detailed information on rail and rack compatibility. This manual provides specifications for supported rack types and instructions for proper installation.


Dell EMC PowerEdge XE8640 Installation and Service Manual: This document provides comprehensive guidelines on the correct installation procedures and compatible rack types for the XE8640 server.

Dell EMC Technical Specifications Guide: Offers detailed specifications on the rack compatibility and rail options for Dell PowerEdge servers, ensuring proper installation and fitment.

Question 2

A deployment engineer is installing a PowerEdge XE8640 server. The rack has four PDUs. Looking at the rear of the rack, one power source provides power to the two left PDUs. A different power

source provides power to the two right PDUs.

What side of the rack should XE8640 PSU 1 and PSU 2 be connected?



Answer : D

Redundancy and Load Balancing:

PowerEdge XE8640 servers are designed for high availability and reliability. One key aspect of this design is the redundancy provided by the server's Power Supply Units (PSUs). By connecting each PSU to a different power source, you ensure that the server remains operational even if one power source fails.

Power Source Configuration:

In this scenario, the rack has two distinct power sources: one supplying power to the two left PDUs and the other to the two right PDUs. To maximize redundancy, each PSU should be connected to a different power source.

PSU Placement:

PSU 1 in the left PDUs: Connect PSU 1 to one of the PDUs on the left side of the rack. This ensures that PSU 1 is powered by the first power source.

PSU 2 in the right PDUs: Connect PSU 2 to one of the PDUs on the right side of the rack. This ensures that PSU 2 is powered by the second power source.

Ensuring Redundancy:

By placing PSU 1 on the left and PSU 2 on the right, you create a redundant power configuration. If either power source fails, the other PSU can continue to supply power to the server, maintaining its operation.

Steps for Connection:

Step 1: Verify that the rack's PDUs are correctly connected to their respective power sources.

Step 2: Identify the left and right PDUs based on their power source connections.

Step 3: Connect PSU 1 to a PDU on the left side of the rack.

Step 4: Connect PSU 2 to a PDU on the right side of the rack.

Step 5: Confirm that both PSUs are securely connected and receiving power from separate sources.

Safety and Verification:

Ensure that all connections are secure and that the cables are managed to prevent interference with other components or airflow within the rack. Verify that each PSU is functioning correctly by checking the server's power status indicators.


Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on PSU connections and power redundancy configurations.

Dell EMC Technical Specifications Guide: Offers comprehensive details on the power requirements and redundancy features of the PowerEdge XE8640.

Question 3

What must be considered regarding stab-in rails with installing a PowerEdge XE server?



Answer : C

Understanding Stab-in Rails:

Stab-in rails are designed to simplify the server installation process. These rails enable a quick and straightforward installation of the server into the rack.

Compatibility and Usage:

Stab-in rails are specifically designed for use in 4-post racks with square holes. This compatibility ensures stability and proper fitting within the rack structure.

Installation Process:

Before initiating the installation, verify that the rack is a 4-post, square hole type.

Position the stab-in rails to align with the square holes on the rack. Typically, stab-in rails have tabs that fit precisely into these square holes.

Mounting the Server:

Once the rails are securely attached to the rack, the server can be mounted. The design of the stab-in rails facilitates a smooth insertion of the server, ensuring it is securely held in place.

Ensuring Proper Fit:

After the server is mounted, check to ensure that it is level and securely attached. This step is crucial to prevent any movement or displacement that could occur due to vibrations or physical disturbances.


Dell EMC PowerEdge XE9680 and XE8640 Installation and Service Manual: This manual provides detailed instructions on the use and installation of stab-in rails, including compatibility with specific rack types.

Dell EMC Technical Specifications Guide: Offers comprehensive specifications and compatibility information for different mounting and installation hardware used with Dell PowerEdge servers.

Question 4

A deployment engineer goes on-site to install a mix of XE systems in a customer testing and development data center. The customer engineering group is stress testing the PowerEdge XE servers to

determine the best XE server for their software applications. As one of the first steps, they must ensure the correct server rails are on-site.

Which three options are a correct matching of rail type with server type?



Answer : B, C, E

To ensure the correct server rails are on-site for the installation of PowerEdge XE servers, it's essential to match the server model with the appropriate rail type. Based on the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix, the following matches are correct:

XE9680 and B25: The XE9680 server is compatible with the B25 rail type, which is designed to support the size and weight of this particular server model1.

XE9640 and B25: Similarly, the XE9640 server can also utilize the B25 rail type for secure mounting in a rack1.

XE9680 and B28: Additionally, the XE9680 server is compatible with the B28 rail type, providing an alternative mounting solution1.

It's important to note that the rail types are specific to the server models and are designed to ensure a secure and stable installation in the customer's rack. The Dell Rail Sizing and Rack Compatibility Matrix provides detailed information on the compatibility of different server models with their respective rail types. This document should be consulted to verify the correct rail type for each server model before proceeding with the installation1.


Question 5

A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to

the four racks.

What power consumption information can the deployment engineer give the data center manager?



Answer : B

The PowerEdge XE9680 server is equipped with power supply units (PSUs) that are essential for its operation. Here's the power consumption information that the deployment engineer can provide:

PSU Specifications: Each PowerEdge XE9680 server comes withfour 2800-Watt, 15.6 Amp PSUs1. This specification is crucial for the data center manager to understand the power requirements for each server.

Total Power Requirement: With two servers per rack, each rack will have a total ofeight 2800-Watt PSUs. This information helps in calculating the total power draw for each rack.

Power Distribution Units (PDUs): While the number of PDUs required for high availability can vary, it's important to note that the server's PSUs feature aC22 input socket1. The data center manager should ensure that the PDUs in the rack are compatible with this type of connection.

Power Planning: The data center manager must plan for the power needed to supply power to the four racks, considering the power draw of the servers and any additional equipment that will be installed.

By providing this detailed power consumption information, the deployment engineer assists the data center manager in planning for the appropriate power infrastructure to support the PowerEdge XE9680 servers.


Question 6

A customer wants to implement 20 PowerEdge XE9680 servers for development and rendering of their studio CGI production. The solution includes a shared development environment with multiple

outside partners, professionals, and hobbyists.

Due to the heating and cooling limitations of the data center, what GPUs should be used for the servers?



Question 7

A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed. They need to update the drivers on the server.

What is a consideration before updating the driver?



Answer : B

Understanding GPU Drivers:

Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.

Driver Packages for Different GPU Models:

For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.

Importance of Model-Specific Drivers:

Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.

Steps to Update Drivers on Linux:

Identify the GPU models installed in the server. This can be done using commands like lspci | grep -i vga or similar tools that list the hardware components.

Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.

Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.

Using iDRAC for Driver Updates:

While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported. Drivers are usually installed within the operating system environment.

Compatibility with Linux:

Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.

Reference to Official Documentation:

Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.


Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.

NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.

Page:    1 / 14   
Total 14 questions