Dell EMC Dell PowerEdge XE9680 and XE8640 Install D-PEXE-IN-A-00 Exam Practice Test

Page: 1 / 14
Total 14 questions
Question 1

A deployment engineer goes on-site to install a mix of XE systems in a customer testing and development data center. The customer engineering group is stress testing the PowerEdge XE servers to

determine the best XE server for their software applications. As one of the first steps, they must ensure the correct server rails are on-site.

Which three options are a correct matching of rail type with server type?



Answer : B, C, E

To ensure the correct server rails are on-site for the installation of PowerEdge XE servers, it's essential to match the server model with the appropriate rail type. Based on the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix, the following matches are correct:

XE9680 and B25: The XE9680 server is compatible with the B25 rail type, which is designed to support the size and weight of this particular server model1.

XE9640 and B25: Similarly, the XE9640 server can also utilize the B25 rail type for secure mounting in a rack1.

XE9680 and B28: Additionally, the XE9680 server is compatible with the B28 rail type, providing an alternative mounting solution1.

It's important to note that the rail types are specific to the server models and are designed to ensure a secure and stable installation in the customer's rack. The Dell Rail Sizing and Rack Compatibility Matrix provides detailed information on the compatibility of different server models with their respective rail types. This document should be consulted to verify the correct rail type for each server model before proceeding with the installation1.


Question 2

A customer wants to implement 20 PowerEdge XE9680 servers for development and rendering of their studio CGI production. The solution includes a shared development environment with multiple

outside partners, professionals, and hobbyists.

Due to the heating and cooling limitations of the data center, what GPUs should be used for the servers?



Question 3

A deployment engineer arrives on-site to install an XE9680 server. The server lift does not have the ability to maneuver beneath the XE9680 shipping pallet.

How many people must you have to physically pick up the server to place it on the lift shelf?



Answer : A

Weight and Size of the PowerEdge XE9680:

The Dell PowerEdge XE9680 server is designed for high performance, which often results in a larger and heavier form factor. Handling such servers typically requires multiple people to ensure safety and prevent damage.

Ergonomic Considerations:

Due to its weight and size, it is crucial to follow proper ergonomic practices when lifting and moving the server. This minimizes the risk of injury and ensures the server is handled safely.

Number of People Required:

For the XE9680, it is recommended to have four people when physically picking up the server to place it on the lift shelf. This recommendation is based on the server's weight and the need to maneuver it safely onto the lift.

Safety and Coordination:

Each person should position themselves on one side of the server, ensuring an even distribution of weight. This coordinated effort helps in lifting the server evenly and reducing the risk of dropping or mishandling it.

Procedure for Lifting:

Two individuals should position themselves at the front corners, and two at the rear corners of the server. On a coordinated count, all four should lift the server together and place it gently onto the lift shelf.

The lift shelf should be stable and able to support the weight of the server once it is placed on it.

Using the Lift:

Once the server is on the lift shelf, it can be maneuvered into the desired position in the rack. Ensure that the lift is rated for the weight of the XE9680 to avoid any mechanical failures.

Reference to Official Documentation:

Dell's installation guides and service manuals typically provide guidelines on the number of personnel required for handling large and heavy servers, ensuring both safety and compliance with best practices.


Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed guidelines on handling and installing the XE9680 server, including the recommended number of personnel required for safe handling.

Dell EMC Technical Specifications Guide: Offers insights into the physical dimensions and weight of the PowerEdge XE9680, informing the need for multiple personnel for safe handling and installation.

Question 4

A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed. They need to update the drivers on the server.

What is a consideration before updating the driver?



Answer : B

Understanding GPU Drivers:

Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.

Driver Packages for Different GPU Models:

For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.

Importance of Model-Specific Drivers:

Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.

Steps to Update Drivers on Linux:

Identify the GPU models installed in the server. This can be done using commands like lspci | grep -i vga or similar tools that list the hardware components.

Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.

Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.

Using iDRAC for Driver Updates:

While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported. Drivers are usually installed within the operating system environment.

Compatibility with Linux:

Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.

Reference to Official Documentation:

Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.


Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.

NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.

Question 5

A deployment engineer is connecting the network cables on an XE9680 server. The data center administrator wants to know why the server does not have an OCP card for network connectivity.

How should the engineer respond to the administrator's query?



Answer : C

Overview of OCP Cards:

Open Compute Project (OCP) cards are network interface cards designed to provide high-speed networking capabilities. They are often used in data center environments to enhance network performance and flexibility.

OCP Card on Dell PowerEdge XE9680:

For the Dell PowerEdge XE9680 server, an OCP card is not a mandatory component. The server can achieve Power-On Self-Test (POST) and function normally without an OCP card.

Optional Component:

The OCP card is considered an optional component for the XE9680 server. This means it can be added based on specific networking needs but is not essential for the server's basic operations.

Networking Alternatives:

The XE9680 server is equipped with various other network interface options. For instance, it has integrated network ports (LAN on Motherboard, or LOM) which provide necessary network connectivity out-of-the-box.

Customization and Upgrades:

The optional nature of the OCP card allows data center administrators to customize their servers based on their network performance requirements. If high-speed or specific networking features are needed, the OCP card can be added accordingly.

Communicating with the Administrator:

The deployment engineer should explain to the data center administrator that while the OCP card is not included by default, it can be added as per the data center's specific networking needs. The server's design supports flexibility in network configurations.


Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed information on the components and optional upgrades available for the XE9680 server.

Dell EMC Networking Guide: This guide outlines various networking options and configurations available for Dell PowerEdge servers, including the role and installation of OCP cards.

Question 6

A deployment engineer is installing an XE9680 server. The network connectivity has 24 optical cables that route to switches in the data center. The administrator questions the use of a cable management arm (CMA).

What are two items to consider when installing a CMA?



Answer : A, B

When installing a Cable Management Arm (CMA) on the Dell PowerEdge XE9680 server, there are specific considerations to ensure proper installation and operation:

CMA Orientation:

Installation Flexibility: The CMA for the XE9680 can be installed to open on either the left or right side of the server. This flexibility allows for better management of space within the rack and ensures that the CMA can accommodate the specific layout of your data center (Dell) (Dell).

Cable Routing:

Avoid Routing Optical Cables Through the CMA: Optical cables are typically more sensitive and less flexible compared to other types of cables. Routing them through the CMA can lead to bending, twisting, or other stresses that may damage the cables and affect network performance. Therefore, it is advised not to route optical cables through the CMA (Dell) (Dell).

Installation Process:

Align and Install the CMA: Attach the CMA to the designated mounting points on the server rails. Ensure that it is securely fastened and aligned properly to avoid any issues when extending or retracting the server from the rack.

Organize Cables: Use the provided cable management features to route and secure other cables, ensuring they are not pinched or overly stressed. Avoid including optical cables in the CMA to prevent potential damage.

Post-Installation Checks:

Verify Movement: Ensure that the server can be smoothly extended and retracted with the CMA in place without any cables getting caught or strained.

Secure Connections: Double-check all cable connections to ensure they are secure and functioning correctly.

These steps are crucial for maintaining the integrity and performance of the server and the connected network infrastructure. Proper cable management not only ensures safety but also enhances the reliability and maintainability of the data center setup.


Dell PowerEdge XE9680 Installation and Service Manual (Dell).

Dell XE9680 Rack Rail with Cable Management Arm Information (Dell) (Dell).

Question 7

What must be considered regarding stab-in rails with installing a PowerEdge XE server?



Answer : C

Understanding Stab-in Rails:

Stab-in rails are designed to simplify the server installation process. These rails enable a quick and straightforward installation of the server into the rack.

Compatibility and Usage:

Stab-in rails are specifically designed for use in 4-post racks with square holes. This compatibility ensures stability and proper fitting within the rack structure.

Installation Process:

Before initiating the installation, verify that the rack is a 4-post, square hole type.

Position the stab-in rails to align with the square holes on the rack. Typically, stab-in rails have tabs that fit precisely into these square holes.

Mounting the Server:

Once the rails are securely attached to the rack, the server can be mounted. The design of the stab-in rails facilitates a smooth insertion of the server, ensuring it is securely held in place.

Ensuring Proper Fit:

After the server is mounted, check to ensure that it is level and securely attached. This step is crucial to prevent any movement or displacement that could occur due to vibrations or physical disturbances.


Dell EMC PowerEdge XE9680 and XE8640 Installation and Service Manual: This manual provides detailed instructions on the use and installation of stab-in rails, including compatibility with specific rack types.

Dell EMC Technical Specifications Guide: Offers comprehensive specifications and compatibility information for different mounting and installation hardware used with Dell PowerEdge servers.

Page:    1 / 14   
Total 14 questions